You have no items in your shopping cart.

Subtotal: £0.00

IMAGE

More Views

CENTRAL HEATING LIQUID INHIBITOR NOISE BUSTER, LEAK SEALER, FLUSHING CHEMICAL 1L

Be the first to review this product

Availability: In stock

£6.19

* Required Fields

£6.19

Details

A high performance inhibitor against formation of scale, rust corrosion, hydrogen gassing, microbiological growth and boiler noise.

Uses 

PC100 INHIBITOR is suitable for all metals including aluminium. Once added PC100 does not need to be replaced unless the system is drained down.

Long lasting protection; will extend the life of the system. Non-toxic, safe to use, environmentally froendly. Non-staining, colourless formualtion. Prevents boiler noise and pin-holing.

PC100 Inhibitor Data (CLICK HERE)

PC100 Inhibitor MSDS (CLICK HERE)

---------------------------------------------------

PC200 CENTRAL HEATING SYSTEM

CONCENTRATED INHIBITOR

CONTAINER SIZE: 300ML

A chemical blend which inhibits corrosion, scale formation, hydrogen gassing and microbiological growth and boiler noise,

presented in a cartridge for easy dosing of closed systems.

Uses

PC200 INHIBITOR is suitable for all metals and plastics in use with domestic central heating systems.

Application

Simple and quick application to open or closed systems via a radiator feed valve or filling loop. Ideal in situations where conventional liquid products are difficult to administer. - 1 tube will treat a typical heating system containing 100L system water. - No need to bleed radiators before injecting. - Time and cost effective system.

PC200 Inhibitor Data (CLICK HERE)

PC200 Inhibitor MSDS (CLICK HERE)

---------------------------------------------------

PC300 UNICLEAN- Universal Cleaner

SIZE:1L

A powerful universal cleaner and passivater for new central heating systems or systems up to 6 months old in accordance with BS7593:1992.

Uses

PC300 UNICLEAN is suitable for all metals including aluminium; no neutralisation required.

Application

Ideal for use prior to application of PC100/200 Inhibitor - Powerful, heavy duty cleaning agent. - Eradicates corrosive flux residues, which could cause rapid pin-holing corrosion of radiators. - Eliminates harmful copper deposits being left in the system.

PC300 Uniclean Data (CLICK HERE)

PC300 Uniclean MSDS (CLICK HERE)

---------------------------------------------------

PC400 FLUSHCHEM-

Flushing Chemical

SIZE:1L

A heavy duty chemical blend for deep cleaning of central heating systems in accordance with BS7593:1992.

Uses

A heavy duty flushing chemical for cleaning boiler heat exchangers, radiators and pipework in domestic central heating systems

Application

Removes corrosion debris and lime scale deposits. -Stops kettling caused by by scale build up and removes cold zones. - Can be used with power flushing machines. - Suitable for use with all metals and alloys including aluminium. Can be used on multi-metal systems. - Totally safe product; non-toxic and non-hazardous.

PC400 Flushchem Data (CLICK HERE)

PC400 Flushchem MSDS (CLICK HERE)

---------------------------------------------------

CENTRAL HEATING SYSTEM LEAK SEALER

PC500 RADLEAK

SIZE:1L

A central heating internal leak sealer.

Uses

PC500 RADLEAK is used for sealing inaccessible leaks and weeping joints in sealed systems. Use of RADLEAK can help avoid costly repairs and It will not block the pump, valve or air vents.

Application

Suitable for reducing pressure loss from sealed systems. - Will not cause pump or air vent blockages. - Suitable for multi-metal systems including those containing aluminium. - Non-hazardous, non-flammable and non-irritant. - High stability, compatible with elastomers. - Readily dispersible.

PC500 Radleak Data (CLICK HERE)

PC500 Radleak MSDS (CLICK HERE)

-----------------------------------------------------

PC600 NOISE BUSTER

SIZE:1L

A central heating boiler noise silencer.

Uses

PC600 NOISE BUSTER is a special blend of chemicals which when added to a central heating system reduces noise from the boiler and radiators due to limescale or sludge build-up. It reduces kettling and knocking.

A non-acidic boiler descaler which stays in the system for life; no need to flush. Knocking and kettling are usually attributable to hard water and limescale and sludge deposit formation on the heat exchanger surfaces. These deposits reduce heat transfer which increases fuel bills and reduces service life of the boiler.

Application

Removes scale and baked on sludge deposits, preventing them from re-forming. - Restores heat efficiency, reduces noise and extends boiler life. - Compatible with plastic tanks, micro-bore and all multi-metal systems including those containing aluminium.

PC600 Noise Buster Data (CLICK HERE)

PC600 Noise Buster MSDS (CLICK HERE)

POSTAGE DISCOUNT AVALIBLE FOR LARGE QUANTITY PURCHASES, EMAIL US FOR MORE INFORMATION!

Additional Information

COLOUR COLOUR

Customer Reviews

Write Your Own Review

You're reviewing: CENTRAL HEATING LIQUID INHIBITOR NOISE BUSTER, LEAK SEALER, FLUSHING CHEMICAL 1L

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Brands

  • brand
  • brand
  • brand
  • brand
  • brand
  • brand